Controle do espaçamento na cavidade de micro-ondas do detector de ondas gravitacionais Mario Schenberg
dc.contributor.advisor | Frajuca, Carlos | |
dc.contributor.author | Amorim, José Alves de | |
dc.date.accessioned | 2017-10-03T23:33:17Z | |
dc.date.available | 2017-10-03T23:33:17Z | |
dc.date.issued | 09/10/2013 | |
dc.description.abstract | O detector de ondas gravitacionais brasileiro, Mario Schenberg, está localizado no Departamento de Física dos Materiais e Mecânica da Universidade de São Paulo (USP), sua massa (ou antena) esférica possui 1,15 toneladas e 65 cm de diâmetro e é constituída por uma liga de cobre-alumínio com 94% de cobre e 6% de alumínio. Ao ser idealizado e desenvolvido pelo grupo Gráviton o projeto previu que ele teria sensibilidade suficiente para captar sinais de amplitudes da ordem de 10-22 Hz-1/2, na faixa de 3000-3400Hz. A fim de alcançar este objetivo o grupo estuda formas de minimizar os ruídos presentes no detector. A pesquisa descrita neste trabalho tem como finalidade atenuar o ruído vibracional existente nos transdutores acoplados ao detector, para tal, será empregada a associação em série de dois capacitores aos transdutores responsáveis por realizar a detecção das ondas gravitacionais. Um capacitor estará ligado a um sistema de molas para ajustar o tamanho do gap (distância entre o poste que carrega a cavidade reentrante de micro-ondas e a membrana que fecha esta cavidade) presente nos transdutores e o segundo será responsável pela comunicação do detector em funcionamento com o meio externo, sem contato mecânico, o sistema terá uma d.d.p. variável para que seja possível manter o gap constante, utilizando um sistema de controle, o qual também será desenvolvido, mesmo na situação em que o detector já esteja funcionando a vácuo e em temperaturas ultra criogênicas. | pt_BR |
dc.description.abstract2 | The Brazilian gravitational wave detector, Mario Schenberg, is located in the Department of Physics of Materials and Mechanics of the University of São Paulo (USP), its mass (or antenna) has spherical 1.15 tons and 65 cm in diameter and consists of a copper-aluminum alloy containing 94% copper and 6% aluminum. To be designed and developed by the project group Gráviton predicted that he would have sufficient sensitivity to capture signals amplitudes of the order of 10-22 Hz-1/2, in the range of 3000-3400Hz. To achieve this goal the group is studying ways to minimize the noise present in the detector. The research described in this paper aims to alleviate the noise existing in the vibrational transducers coupled to the detector to this end, will be used the association of two capacitors in series to the transducers responsible for performing the detection of gravitational waves. A capacitor is connected to a spring system to adjust the size of the gap (distance between the pole that carries microwave reentrant cavity and the membrane which closes the cavity) present in the transducer and the second will be responsible for communication with the detector operating in the external environment, without mechanical contact, the system will have a potential diference variable so that the gap can be maintained constant using a control system, which will also be developed even in a situation in which the switch is already operating at vacuum and ultra cryogenic temperatures. | |
dc.identifier.bibliographicCitation | AMORIM, José Alves de. Controle do espaçamento na cavidade de micro-ondas do detector de ondas gravitacionais Mario Schenberg. 2013. 90 f. Orientador: Carlos Frajuca. Dissertação (Mestrado Profissional em Automação e Controle de Processos) - Instituto Federal de Educação, Ciência e Tecnologia de São Paulo, IFSP, 2013. Versão eletrônica. | |
dc.identifier.uri | http://repo.ifsp.edu.br/123456789/82 | |
dc.publisher | Instituto Federal de Educação, Ciência e Tecnologia de São Paulo (IFSP) | |
dc.publisher.campi | SÃO PAULO | |
dc.publisher.program | Mestrado Profissional em Automação e Controle de Processos | |
dc.rights | Attribution-NonCommercial-NoDerivs 3.0 Brazil | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/br/ | |
dc.subject.keywords | Ondas gravitacionais | |
dc.subject.keywords | Transdutores paramétricos | |
dc.subject.keywords | Detectores de massa ressonante | |
dc.subject.keywords | Detector Mario Schenberg | |
dc.title | Controle do espaçamento na cavidade de micro-ondas do detector de ondas gravitacionais Mario Schenberg | pt_BR |
dc.title.alternative | Spacing control in the microwave cavity of the Mario Schenberg gravitational wave detector | |
dc.type | Teses e Dissertações |