Emprego de topologia boost semicontrolada para mitigação do conteúdo harmônico de corrente em conversores de 12 pulsos
dc.contributor.advisor | Falcondes , José Mendes de Seixas | |
dc.contributor.author | Pelicer Junior, João Carlos | |
dc.contributor.referee | Paschoareli Junior, Dionizio | |
dc.contributor.referee | Souza, Julio Borges de | |
dc.contributor.referee | Brito, Moacyr Aureliano Gomes | |
dc.contributor.referee | Oliveira, Priscila da Silva | |
dc.date.accessioned | 2024-08-07T20:20:50Z | |
dc.date.available | 2024-08-07T20:20:50Z | |
dc.date.issued | 2019-01-21 | |
dc.description.abstract | Os conversores multipulsos têm sido muito utilizados para a melhoria da qualidade de energia elétrica em sistemas de retificação trifásicos. O principal motivo para tal afirmação é a robustez apresentada por esses conversores, aliada às características intrínsecas da estrutura, que resulta no cancelamento natural de certas componentes de corrente na rede, devido ao defasamento angular provocado pela ação do transformador ou autotransformador utilizado. O que se propõe nesse trabalho é a substituição de cada ponte retificadora a diodos, presente no conversor de 12 pulsos, por uma topologia retificadora trifásica semicontrolada, baseada no conversor boost operando no modo de condução descontínuo (MCD), de modo que, seja possível reduzir de maneira significativa a DHT i (Distorção Harmônica Total de corrente), bem como, incorporar os volumosos transformadores de interfase (IPTs) aos indutores boost de alta frequência, resultando na redução de peso e volume. Foram confeccionadas duas versões do conversor de 12 pulsos com retificadores semicontrolados, uma utilizando transformador isolador e a outra um autotransformador. O que se verificou para ambas as configurações é que a estrutura apresenta um reduzido conteúdo harmônico de corrente se comparado ao conversor tradicional e que, ao se operar no modo de condução descontínuo, faz-se possível o emprego de uma lógica de controle simples, possibilitando assim empregar somente uma malha de tensão, e reduzir significativamente a DHT i do conversor. | |
dc.description.abstract2 | Multipulse converters have been widely employed for electrical power quality improvement in three-phase rectifiers systems. The main reason for this statement is the robustness shown by these structures, allied to their natural characteristics, resulting in harmonic canceling at the mains, due to the phase displacement provided by the transformer/autotransformer. In this work, it is proposed the replacement of each rectifier bridge, present in the 12-pulse converter, by a three-phase half-controlled rectifier topology, based on DCM (Discontinuous Conduction Mode) boost converter, thus making it possible to significative reduce the THD i (Total Harmonic Distortion) of the current injected on the mains by the structure. It also incorporates the voluminous IPT's (Interphase Transformer) in the boost high-frequency inductor, resulting in a reduction of weight and size. Two versions of the 12-pulse converter with semicontrolled rectifiers were made, one using an isolating transformer and other using an autotransformer. It was verified that both configurations present a reduced THD i when compared to the traditional converter. So, by electing DCM, it is possible to employ a simpler control logic, employing only one voltage loop and significantly reducing the THD i. | |
dc.format.mimetype | application/pdf | |
dc.identifier.bibliographicCitation | PELICER JÚNIOR, João Carlos. Emprego de tecnologia boost semicontrolada para mitigação do conteúdo harmônico de corrente em conversores de 12 pulsos. 2019. 126 f. Tese (Doutorado em Engenharia Elétrica) - Universidade Estadual Paulista Júlio de Mesquita Filho, Ilha Solteira, 2019. Disponível em: https://repositorio.unesp.br/items/e00df2a6-67a3-4733-8074-cd84644987cb. Acesso em: mar. 2024. | |
dc.identifier.uri | http://hdl.handle.net/11449/180812 | |
dc.identifier2.lattes | 0364467132667801 | |
dc.publisher | Universidade Estadual Paulista (UNESP) | |
dc.publisher.campi | SOROCABA | |
dc.publisher.program | Pós-Graduação em Engenharia Elétrica, Campus de Ilha Solteira, Universidade Estadual Paulista "Júlio de Mesquita Filho" | |
dc.rights | Attribution-NonCommercial-NoDerivs 3.0 Brazil | en |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/br/ | |
dc.subject.keywords | Conversor boost | |
dc.subject.keywords | Conversor multipulso | |
dc.subject.keywords | Distorção harmônica total | |
dc.subject.keywords | Fator de potência | |
dc.subject.keywords | Retificador semicontrolado | |
dc.title | Emprego de topologia boost semicontrolada para mitigação do conteúdo harmônico de corrente em conversores de 12 pulsos | |
dc.title.alternative | Use of semi-controlled boost topology to mitigate current harmonic content in 12-pulse converters | |
dc.type | Teses e Dissertações |